YG368 Automatic Yarn Crimp Tester: Precision Measuring for Fiber Shrinkage by China Factory Suppliers
YG368 Automatic Yarn Crimp Contraction & Shrinkage Tester
The computer-controlled instrument YG368 automatic yarn crimp contraction and shrinkage tester is used for the test of the crimp contraction and boiling water contraction of textured filament yarns (polyester, nylon, and polypropylene).
In testing process, there are functions of automatic changing load, adding load, automatic timing, auto-measure length and automatic calibrate zero. Test results are automatically computed and printed.
Technical Specification
The instrument consists of six parts: oven, electronic balance, test stands, industrial computer and printer. The appearance is like picture 1.
The main technical parameters are as follows:
| Load force | 2.5–5000 cN (arbitrarily set & automatically applied), accuracy 0.2 cN |
| Sample length | 1000 mm |
| Length resolution | 0.04 mm |
| Test indicators | Crimp contraction CC (%), Crimp modulus CM (%), Crimp stability CS (%), Shrinkage S (%) and its mean, standard deviation, CV values. |
| Data input | Via keyboard and mouse |
| Data output | Screen display, printing by printer |
| Number of test samples at one time | 30 |
| Power | 220V, 50Hz, 0.5 KW, oven: 4.8 KW |
| Compressed air | (0.4–0.8) MPa |
| Data storage and query | |
Main Features
- Controlled by IPC, enhancing the reliability of the whole machine.
- Uses imported high-precision electronic scale for high precision and good reproducibility.
- Test data is automatically saved to facilitate management and application.
- The software can automatically change parameters according to user's request for quality manager analysis.
- Instrument can be easily connected to the Internet with a network card.

Picture 1
Crimp stability CM (%) = [ (Lg − Lf) / Lg ] × 100%
Crimp modulus CS (%) = [ (Lg − Lb) / (Lg − Lz) ] × 100%
It is a test instrument for fully automatic length measurements on yarn hanks, characterized by its high flexibility in terms of test sequence configuration, choice of measuring loads and time-intervals for the loading- and unloading periods.