Vacuum Cleaning Furnace for Chemical Fiber Industry - Top China Suppliers & Factory Solutions
Product Introduction
Vacuum Cleaning Furnace is designed for cleaning spin pack body, spinneret, and candle filter, spinning meter pump, other spinning components, especially suitable for profiled, fine denier spinnerets in synthetic fiber production industry, such as PET, PA, PP as well mould in plastic extrusion field.

Principle
Example of Cleaning Process Setting
Cleaning process and its program setting depends on the character of spinnerets, candle filters and work pieces to be cleaned, property of polymers as well.
Hereafter it is the example of cleaning work pieces used on polyester staple fiber spinning systems.
- 1 OA Phase: In 0–50 minutes, heating work pieces up to temperature 350℃.
- 2 AB Phase: Keeping temperature at 350℃ of inner furnace for about 50–150 minutes. During this period more than 80% molecular polymer on the work-piece are molten and flow into waste collecting tank. This phase can be increased or decreased according to the quantity of molecular polymer to be cleaned.
- 3 After AB phase, switching on solenoid valve and vacuum pump.
- 4 BC/CD/DE/EF Phase: At the temperature of about 490–500℃ in about 150–480 minutes, under the conditions of vacuum, high temperature and low oxygen, the residuals of molecular polymers are fully oxidative degraded. The work pieces to be thoroughly cleaned or not takes place during this key period.
- 5 After EF Phase (Cooling Period): The power for heating elements and water supply are stopped; only instruments are powered on.
At the same time, by rinsing and pump, Carbon, vapor and substances are discharged out of furnace.

Maximum temperature is set at 490℃, running time 8 hours; after 90 minutes heating, vacuum pump starts.
In order to improve the cleaning effect and increase the life time of work pieces, after taking out of vacuum cleaning furnace, the subsequent process should be carried out, but depending on specific conditions.
- 1 Put spinnerets, candle filters or other elements into hot water tank to rinse for about 20 minutes.
- 2 Then carry these work pieces into ultrasonic cleaning unit for about 30 minutes, ultrasonic frequency 25~40 kHz.
- 3 After rinsing inside ultrasonic cleaning unit, dry it by compressed air before examination under microscope.
- 4 In case of silicone oil adhering to the surface of work pieces, before ultrasonic treatment, put it inside KOH solution at concentration 20%, temperature 60~70℃ for about 2 hours, then neutralization treatment with oxalic acid.
Hereafter some dimension is listed. We provide any dimension as requested.
Model |
Hearth Dimension (L×W×H) |
Heating / Vacuum Pump (KW) |
Vacuum Level (MPa) |
Designing Temperature (℃) |
Precision (±℃) |
|
LZKL Furnace |
LZKL-A |
φ500×600 |
18/2.2 |
-0.07~-0.085 |
600 |
2 |
LZKL-B |
φ600×800 |
21/2.2 |
-0.07~-0.085 |
600 |
2 |
|
LZKL-C |
φ800×1000 |
30/4 |
-0.07~-0.085 |
600 |
2 |
|
LZKL-D |
φ1000×1200 |
36/4 |
-0.07~-0.085 |
600 |
2 |
|
WZKL Furnace |
WZKL-A |
φ500×600 |
18/2.2 |
-0.07~-0.085 |
600 |
2 |
WZKL-B |
φ600×900 |
21/2.2 |
-0.07~-0.085 |
600 |
2 |
|
WZKL-C |
φ800×1000 |
30/4 |
-0.07~-0.085 |
600 |
2 |
|
WZKL-D |
φ1000×1500 |
36/4 |
-0.07~-0.085 |
600 |
2 |
|
WZKL-E |
φ1700×4800 |
234/18.5 |
-0.07~-0.085 |
600 |
2 |
|
JZKL Furnace |
JZKL-A |
600×400×400 |
18/2.2 |
-0.07~-0.085 |
600 |
2 |
JZKL-B |
600×400×400 |
21/2.2 |
-0.07~-0.085 |
600 |
2 |
|
JZKL-C |
1000×800×600 |
30/4 |
-0.07~-0.085 |
600 |
2 |
|
JZKL-D |
1200×800×800 |
36/4 |
-0.07~-0.085 |
0.45 |
2 |
|