TEG Cleaning Furnace for Polymer Residue Removal – Reliable China Suppliers & Factory Solutions
Product Introduction
TEG is safe, nontoxic, colorless, transparent, neutral liquid. When it is heated to boiling temperature, which is 285℃ under atmospheric pressure, it can alcoholize and dissolve high molecular polymers, so that the work pieces can be cleaned thoroughly. TEG cleaning furnace utilizes this characteristic to place the spinneret, metering pump, and filter element adhered with high molecular weight polymer in a cleaning tank filled with TEG solution for hot boiling, achieving the purpose of cleaning.
Technical Specification
1. Inner tank is made by 1Cr18Ni9T steel as for rinse container. Cooling jacket is equipped outside inner tank to cool the triglycol (TEG) solution after cleaning. Insulating cotton is filled between cooling jacket and outer tank. The tank is separately equipped with outlets for heater, waste discharge and maintenance.
2. Condenser: it is installed on the upper left of the tank. Cold water, as cool medium, passes through interlayer of condenser in order to condensate vapor TEG, which then is collected and recycled.
3. Electric heating device: it is divided into two groups, stainless heater tube in flange type directly inserted into TEG solution. Each group consists of 6 pipes, in "Y" connection.
4. Basket: it is used to contain work pieces to be cleaned.
5. Controller: automatically temperature controller, digital display, which main circuit adopts non-contact control, with over temperature alert function.
Cleaning Process
- 1 Disassemble filtering devices so that most high molecular polymers flow out. Unscrew all screws and similar parts, then place all work pieces into the basket.
- 2 Fill the tank with TEG solution to approximately 70–75% of the tank volume.
- 3 Soak the basket with work pieces into the tank, switch on the instrument and heating device, and set the temperature to 285℃.
- 4 Open the flow controller valve to 0–100 L/H, and open the condenser valve.
- 5 Stop heating and maintain at 285℃. After 6–8 hours, open the cooling device to cool down the TEG solution.
- 6 When the TEG solution drops below 50℃, close the cooling valve, open the furnace lid, and remove the basket.
- 7 Move the basket into water at 95℃, then into an alkaline solution tank at 60–70℃, and finally rinse in hot water. For spinnerets, candle filters, and other precision parts, additional cleaning with an ultrasonic cleaning unit is required.
By now, the cleaning process is completed. Below are some standard dimensions. Custom dimensions are available upon request.
| Model | Dimension (Dia.×H) | Voltage / KW | Temperature Precision | Work Hour |
|---|---|---|---|---|
| RTL-3 | φ320×800 | 380V / 9KW | ±1℃ | ≤8h |
| RTL-4 | φ420×900 | 380V / 12KW | ±1℃ | ≤8h |
| RTL-5 | φ500×1000 | 380V / 24KW | ±1℃ | ≤8h |
| RTL-6 | φ650×1200 | 380V / 32KW | ±1℃ | ≤12h |
| RTL-8 | φ800×1200 | 380V / 54KW | ±1℃ | ≤16h |
| RTL-10 | φ1000×1800 | 380V / 63KW | ±1℃ | ≤16h |
| RTL-12 | φ1200×2500 | 380V / 98KW | ±1℃ | ≤16h |
Product Features
Low-Temperature Operation
Safe and Non-Toxic
Good Cleaning Effect
No Damage to Equipment
Extends Service Life of Spinnerets, Metering Pumps, Pack Bodies & Candle Filters
Application Industry
- 🧵 Chemical Fiber Industry: Used for cleaning key components such as spinnerets, screw dies, spin pack bodies and candle filters, removing polymer residues, and ensuring fiber production quality.
- 🔩 Plastic Industry: Suitable for cleaning injection molding machine heads, filters, metering pumps and other equipment to remove high polymer melt dirt.
- 📦 Film Packaging Industry: Specifically used for cleaning mold heads and Leaf Disc Filters.
Frequently Asked Questions
TEG (Triethylene Glycol) is a safe, nontoxic, colorless, and neutral liquid. At its boiling point of 285℃ under atmospheric pressure, it can alcoholize and dissolve high molecular weight polymers, making it highly effective for thoroughly cleaning components such as spinnerets, metering pumps, and filter elements.
A standard cleaning cycle takes approximately 6–8 hours at 285℃, followed by a cooling phase until the TEG solution drops below 50℃. For larger models such as RTL-8, RTL-10, and RTL-12, the work hour may extend up to 16 hours.
The TEG cleaning furnace is widely used in the chemical fiber industry (spinnerets, metering pumps, candle filters), the plastic industry (injection molding heads, filters), and the film packaging industry (mold heads, Leaf Disc Filters).
Yes. TEG is nontoxic and chemically neutral. The furnace is equipped with a condenser that captures and recycles evaporated TEG vapor, minimizing waste and ensuring a safe working environment.
Standard models range from RTL-3 (φ320×800mm, 9KW) to RTL-12 (φ1200×2500mm, 98KW), covering a wide range of production scales. Custom dimensions and specifications can be provided upon request to meet specific application requirements.
Yes. After TEG cleaning, precision parts such as spinnerets and candle filters should be further processed in hot water (95℃), an alkaline solution tank (60–70℃), and finally rinsed in hot water. An ultrasonic cleaning unit is also recommended for components with strict cleanliness requirements.