Inquiry
Form loading...
High-Precision Metering Pumps for Synthetic Fiber Spinning - China Suppliers & Factory for Textile Manufacturing
Hot Products

High-Precision Metering Pumps for Synthetic Fiber Spinning - China Suppliers & Factory for Textile Manufacturing

A spinning metering pump is an essential precision device in the chemical fiber industry, specifically designed for the accurate measurement and transportation of polymer solutions or melts throughout the spinning process. This pump guarantees consistent fiber quality by precisely maintaining flow rates and pressure, making it an indispensable tool for manufacturers in China. Typically equipped with a gear or screw mechanism, the pump delivers fluids in controlled volumes, significantly reducing fluctuations, Manufactured from corrosion-resistant materials such as stainless steel or alloy steel, these pumps are built to endure harsh chemical environments. They are commonly utilized in the production of polyester, nylon, and polypropylene, where high accuracy (±0.5% or better) is crucial for achieving uniformity and strength in synthetic fibers. The design minimizes pulsation, thereby enhancing process stability and efficiency, As one of the leading suppliers and factories of spinning metering pumps in China, we provide high-quality solutions that support scalable manufacturing in textiles, industrial materials, and medical applications. Our pumps bridge the gap between polymer preparation and fiber formation, ensuring optimal performance in various production environments

    Spinning Pump

    Spinning metering pumps are core precision components in chemical fiber production, mainly divided into spinning pumps (commonly known as metering pumps) that transport spinning melt or solution, and oil pumps that transport oil agents. They work together and play a decisive role in the uniformity and quality of the final fiber product.

    ⚙️
    The core measuring device in chemical fiber production, which achieves precise measurement and transportation of polymer melt or solution through gear meshing. Its function is to uniformly transport the melt (such as polyester, nylon) or solution (such as spandex, acrylic) to the spinneret under constant pressure, ensuring uniform fiber density and directly affecting the quality of the finished product (such as uniformity and strength).

    According to the different spinning fluids measured and transported, spinning pumps are divided into two types.

    Melt spinning pumps are mainly used in melt spinning processes such as polyester, nylon, and polypropylene. Its main components include: upper cover plate, lower cover plate, middle plate (8-shaped plate), a pair of working gears located in the 8-shaped holes, two shafts, and connecting shafts. The drive shaft of the spinning pump drives the driving shaft to rotate through the connecting shaft, and the working gear is driven by the key to operate. With the rotation of the gear, the spinning melt in the suction chamber continuously fills the tooth valley and is brought to the extrusion chamber. When the teeth of the two gears mesh with each other, the volume of the extrusion chamber decreases, and the melt is then pressed towards the nozzle. The working temperature of this type of spinning pump is nearly 300 ℃, and the temperature during cleaning can reach up to 450 ℃. Therefore, it is required that the material of the spinning pump must not deform at high temperatures and have good wear resistance.

    spinning pump2

    The solution spinning pump is applied in solution spinning processes such as acrylic fiber and viscose fiber. The operating temperature of this type of pump is relatively low. Based on the properties of the spinning solution, corrosion-resistant and wear-resistant materials are selected for manufacturing.

    Spinning Pump Structure

    Gear pumps are the main type, using high-precision gears (with small module and multiple teeth), consisting of a base plate, gear plate, cover plate, transmission shaft, and inlet and outlet channels. Melt pumps need to withstand high temperatures (nearly 300 ℃), while solution pumps are suitable for corrosive media.

    • Sealing Design: The bottom plate and connecting surface are sealed with grooves to prevent melt leakage.
    • Working Principle: Based on volumetric conveying. The rotation of the driving gear drives the reverse rotation of the driven gear, and the volume change during gear meshing achieves suction and discharge, ensuring continuous and stable fluid transportation.

    Spinning Pump Parameters

    🔹 Displacement Range: 0.15–30 CC/r (small to large displacement), accuracy ±3%

    🔹 Working Conditions: Temperature ≤ 300 ℃ (melt pump), pressure ≤ 30 MPa, speed 5–200 r/min

    🔹 Material: Stainless steel or high-temperature alloy, ensuring wear resistance and corrosion resistance

    Spinning Pump Application

    • Polyester / Nylon Short Thread: Precise control of melt flow rate through gear pump to ensure fiber uniformity.
    • Production of Spandex: The high-pressure pump meets the pressure requirements of 300–500 kg/cm², ensuring the quality of elastic fibers.
    • Composite Spinning: Planetary or composite pumps achieve synchronous transportation of two polymers for functional fiber production.

    8 Outlet Spinning Pump

    📌 Here is an introduction to a spinning pump. If you need other types, please contact us.

    🔹 Main Application: Spinning process of the filament of POY and FDY

    🔹 Number of Inlet Ports: 1

    🔹 Number of Outlet Ports: 8

    🔹 Outlet Pressure: 50 MPa

    🔹 Speed Range: 10–40 rpm

    🔹 Max Differential Pressure: 40 MPa

    🔹 Operation Temperature: < 350 ℃

    🔹 Cleaning Temperature: < 450 ℃

    8 Outlet Spinning Pump
    Computer Number Type Capacity Per Port (cc/rev) Dimension (mm)
    H1 H
    F3024801 FTB8X2.4-160 2.4 88.3 163.3
    F3030801 FTB8X3.0-160 3.0 90 165
    F3035801 FTB8X3.5-160 3.5 91.6 166.6
    F3036801 FTB8X3.6-160 3.6 92 167
    F3040801 FTB8X4.0-160 4.0 93.2 168.2
    F3045801 FTB8X4.5-160 4.5 94.8 169.8
    F3055801 FTB8X5.5-160 5.5 98.2 173.2

    Oil Pump

    Specially designed for adding spinning oil to ensure stable formation of fiber bundles and improve product quality. Oil pump can reduce friction between fibers, prevent static electricity generation, and better bond the fiber bundles together. The oil pump can precisely control the amount of oil used, with an error of less than 1%, ensuring that each fiber bundle can be evenly oiled. This effectively avoids problems such as fuzz, breakage, and merging, and is particularly suitable for high-speed spinning processes of synthetic fibers such as polyester and nylon (speeds exceeding 3000 meters per minute), helping to improve the strength and uniformity of the finished yarn.

    Oil Pump

    Oil Pump Structure

    • Gears: Require corrosion resistance, high temperature resistance, and key sealing design (such as combination sealing). The high-pressure oil pump needs to adapt to high pressure (up to 30 MPa) to ensure uniform coating of the oil.
    • Function Extension: Partial design integrated detection device, real-time monitoring of flow and pressure, supporting intelligent control.

    Oil Pump Parameters

    🔹 Temperature Resistance: Suitable for setting temperatures of 130–150 ℃; the oil agent needs to resist thermal decomposition.

    🔹 Uniformity: By precise measurement, the oil agent is ensured to be evenly distributed on the fiber surface, reducing static electricity and friction.

    Application of Oil Pump

    • Polyester FDY: The oil agent has high temperature resistance and avoids the formation of oil stains on the hot roller, reducing the breakage of fibers.
    • High Speed Spinning: Uniform oiling ensures smooth fiber bundles and reduces the risk of production interruption caused by static electricity.

    16 Outlet Oil Pump

    📌 Here is an introduction to an oil pump. If you need other types, please contact us.

    🔹 Number of Inlet Ports: 1

    🔹 Number of Outlet Ports: 16

    🔹 Speed Range: 10–60 rpm

    🔹 Operation Temperature: < 50 ℃

    Computer Number Type Capacity Per Port (cc/rev) Dimension (mm)
    S H1 H
    FY00081601 FYB16X0.08 0.08 15.4 84.6 112
    FY00101601 FYB16X0.10 0.10 15.6 85.4 113
    FY00121601 FYB16X0.12 0.12 15.9 86.7 114
    FY00151601 FYB16X0.15 0.15 16.4 88.6 116
    FY00201601 FYB16X0.20 0.20 17.2 91.8 119
    FY00301601 FYB16X0.30 0.30 18.8 98.2 126
    16 Outlet Oil Pump

    Instructions for Using High-Pressure Melt Spinning Metering Pump

    Installation and Operation of the Pump

    1. Spray a small amount of silicone oil into the inlet hole of the cleaned metering pump, and use a special tool to rotate the transmission sleeve for initial lubrication (for use with a new pump, there is no need to disassemble and clean).
    2. Place the pump into the waste heat furnace and raise the temperature at a rate not exceeding 100 ℃/H. The spinning process requires the spinning box temperature to be raised, and perform insulation preheating (4–6 hours).
    3. Install the preheated pump onto the spinning box pump seat, use specialized positioning screws to secure the pump, and keep it warm for about 4 hours before starting to operate.
    4. When driving, first rotate the flange of the spinning machine drive shaft by hand to drive the pump body to rotate smoothly and evenly. You can start the machine and open the feed inlet needle valve in a timely manner to allow the melt to flow into the inlet of the metering pump, preventing the pump shaft from running empty.
    5. In order to prevent accidental damage to the metering pump during operation, the spinning machine drive shaft must have a safety pin (or key) with a strength lower than that of the key on the pump drive shaft.

    Cleaning and Disassembly of Pumps

    1. Place the pump into the box type electric furnace and heat it up to 380–420 degrees at a rate not exceeding 100 degrees/H to carbonize the slurry before disassembly.
    2. Brush the decomposed parts with a nylon brush to remove surface carbides, and clean them thoroughly by placing them in kerosene.
    3. After the metering pump is removed from the spinning box, it should not be rapidly cooled to prevent deformation or cracking of the parts.
    4. The working environment for disassembling, assembling, and repairing metering pumps should be clean and tidy to prevent debris and metal from entering the pump, affecting its accuracy or accidentally damaging its parts.
    5. Each set of pump should establish a record card to record the use, maintenance, damage, flow rate, and other information of the pump.

    Frequently Asked Questions (FAQ)

    Q What is the main difference between a melt spinning pump and a solution spinning pump?
    Melt spinning pumps are designed for high-temperature melt processes (polyester, nylon, polypropylene) and must withstand working temperatures of nearly 300 ℃ and cleaning temperatures up to 450 ℃. Solution spinning pumps are used for lower-temperature solution processes (acrylic, viscose) and are manufactured from corrosion-resistant and wear-resistant materials suited to the chemical properties of the spinning solution.
    Q What displacement range and accuracy does a spinning metering pump offer?
    Spinning metering pumps typically offer a displacement range of 0.15–30 CC/r, covering both small and large displacement requirements. The measurement accuracy is ±3%, ensuring consistent and uniform fiber output throughout the production process.
    Q What are the key specifications of the 8 Outlet Spinning Pump?
    The 8 Outlet Spinning Pump features 1 inlet port and 8 outlet ports, an outlet pressure of 50 MPa, a maximum differential pressure of 40 MPa, a speed range of 10–40 rpm, an operation temperature below 350 ℃, and a cleaning temperature below 450 ℃. It is primarily used in POY and FDY filament spinning processes.
    Q Why is an oil pump important in the chemical fiber spinning process?
    The oil pump precisely controls the amount of spinning oil applied to fiber bundles, with an error of less than 1%. It reduces friction between fibers, prevents static electricity generation, and helps bond fiber bundles together. This is especially critical in high-speed spinning processes (speeds exceeding 3000 m/min) for synthetic fibers such as polyester and nylon, improving yarn strength and uniformity while preventing fuzz, breakage, and merging.
    Q How should a high-pressure melt spinning metering pump be properly installed?
    Before installation, spray a small amount of silicone oil into the inlet hole for initial lubrication. Place the pump in a waste heat furnace and raise the temperature at no more than 100 ℃/H, then preheat for 4–6 hours. After mounting onto the spinning box pump seat and securing with positioning screws, maintain warmth for approximately 4 hours before operation. Always ensure the drive shaft has a safety pin weaker than the pump drive shaft key to prevent damage.
    Q What precautions should be taken when cleaning and disassembling a metering pump?
    Heat the pump in a box-type electric furnace to 380–420 ℃ at a rate not exceeding 100 ℃/H to carbonize residual slurry before disassembly. Use a nylon brush to remove surface carbides and clean parts thoroughly in kerosene. Avoid rapid cooling after removal from the spinning box to prevent deformation or cracking. Maintain a clean working environment to prevent debris or metal particles from entering the pump, and keep a detailed record card for each pump covering usage, maintenance, damage, and flow rate.