A spinning metering pump is a vital precision device widely used in the chemical fiber industry in China. It plays a crucial role in accurately measuring and transporting polymer solutions or melts during the spinning process, ensuring consistent fiber quality. This pump operates using a gear or screw mechanism, delivering fluid at controlled volumes while maintaining precise flow rates and pressure, significantly minimizing fluctuations, Manufactured from corrosion-resistant materials such as stainless steel or alloy steel, this pump is designed to withstand harsh chemical environments, making it ideal for leading suppliers and factories in polyester, nylon, and polypropylene production. With a high accuracy rate of ±0.5% or better, it directly impacts the uniformity and strength of the fibers produced. Additionally, its innovative design reduces pulsation, enhancing overall process stability, As a critical component that bridges polymer preparation and fiber formation, the spinning metering pump enables efficient and scalable manufacturing of synthetic fibers. It is essential for producing high-quality textiles, industrial materials, and medical applications, making it a preferred choice among China’s top suppliers and factories

    Spinning Pump

    Spinning metering pumps are core precision components in chemical fiber production, mainly divided into spinning pumps (commonly known as metering pumps) that transport spinning melt or solution, and oil pumps that transport oil agents. They work together and play a decisive role in the uniformity and quality of the final fiber product.

    The core measuring device in chemical fiber production, which achieves precise measurement and transportation of polymer melt or solution through gear meshing. Its function is to uniformly transport the melt (such as polyester, nylon) or solution (such as spandex, acrylic) to the spinneret under constant pressure, ensuring uniform fiber density and directly affecting the quality of the finished product (such as uniformity and strength).

    According to the different spinning fluids measured and transported, spinning pumps are divided into two types.

    Melt spinning pumps are mainly used in melt spinning processes such as polyester, nylon, and polypropylene. Its main components include: upper cover plate, lower cover plate, middle plate (8-shaped plate), a pair of working gears located in the 8-shaped holes, two shafts, and connecting shafts. The drive shaft of the spinning pump drives the driving shaft to rotate through the connecting shaft, and the working gear is driven by the key to operate. With the rotation of the gear, the spinning melt in the suction chamber continuously fills the tooth valley and is brought to the extrusion chamber. When the teeth of the two gears mesh with each other, the volume of the extrusion chamber decreases, and the melt is then pressed towards the nozzle. The working temperature of this type of spinning pump is nearly 300 ℃, and the temperature during cleaning can reach up to 450 ℃. Therefore, it is required that the material of the spinning pump must not deform at high temperatures and have good wear resistance.

    Spinning Pump

    The solution spinning pump is applied in solution spinning processes such as acrylic fiber and viscose fiber. The operating temperature of this type of pump is relatively low. Based on the properties of the spinning solution, corrosion-resistant and wear-resistant materials are selected for manufacturing.

    Spinning Pump Structure

    Gear pumps are the main type, using high-precision gears (with small module and multiple teeth), consisting of a base plate, gear plate, cover plate, transmission shaft, and inlet and outlet channels. Melt pumps need to withstand high temperatures (nearly 300 ℃), while solution pumps are suitable for corrosive media.

    Sealing Design: The bottom plate and connecting surface are sealed with grooves to prevent melt leakage.

    Working Principle: Based on volumetric conveying. The rotation of the driving gear drives the reverse rotation of the driven gear, and the volume change during gear meshing achieves suction and discharge, ensuring continuous and stable fluid transportation.

    Spinning Pump Parameters

    Displacement Range
    0.15 – 30 CC/r
    Accuracy
    ± 3%
    Temperature (Melt)
    ≤ 300 ℃
    Max Pressure
    ≤ 30 MPa
    Speed Range
    5 – 200 r/min
    Material
    Stainless Steel / High-Temp Alloy

    Spinning Pump Applications

    Polyester / Nylon Short Thread
    Precise control of melt flow rate through gear pump to ensure fiber uniformity.
    Production of Spandex
    High-pressure pump meets 300–500 kg/cm² requirements, ensuring elastic fiber quality.
    Composite Spinning
    Planetary or composite pumps achieve synchronous transportation of two polymers for functional fiber production.

    8 Outlet Spinning Pump

    Here is an introduction to a spinning pump. If you need other types, please contact us.
    Main Application
    POY & FDY Filament Spinning
    Inlet Ports
    1
    Outlet Ports
    8
    Outlet Pressure
    50 MPa
    Speed Range
    10 – 40 rpm
    Max Differential Pressure
    40 MPa
    Operation Temperature
    < 350 ℃
    Cleaning Temperature
    < 450 ℃
    8 Outlet Spinning Pump
    Computer Number Type Capacity Per Port (cc/rev) Dimension (mm)
    H1 H
    F3024801 FTB8X2.4-160 2.4 88.3 163.3
    F3030801 FTB8X3.0-160 3.0 90 165
    F3035801 FTB8X3.5-160 3.5 91.6 166.6
    F3036801 FTB8X3.6-160 3.6 92 167
    F3040801 FTB8X4.0-160 4.0 93.2 168.2
    F3045801 FTB8X4.5-160 4.5 94.8 169.8
    F3055801 FTB8X5.5-160 5.5 98.2 173.2

    Oil Pump

    Specially designed for adding spinning oil to ensure stable formation of fiber bundles and improve product quality. Oil pump can reduce friction between fibers, prevent static electricity generation, and better bond the fiber bundles together. The oil pump can precisely control the amount of oil used, with an error of less than 1%, ensuring that each fiber bundle can be evenly oiled. This effectively avoids problems such as fuzz, breakage, and merging, and is particularly suitable for high-speed spinning processes of synthetic fibers such as polyester and nylon (speeds exceeding 3000 meters per minute), helping to improve the strength and uniformity of the finished yarn.

    Oil Pump

    Oil Pump Structure

    Gears: Require corrosion resistance, high temperature resistance, and key sealing design (such as combination sealing). The high-pressure oil pump needs to adapt to high pressure (up to 30MPa) to ensure uniform coating of the oil.

    Function Extension: Partial design integrated detection device, real-time monitoring of flow and pressure, supporting intelligent control.

    Oil Pump Parameters

    Temperature Resistance
    130 – 150 ℃
    Oil Dosing Error
    < 1%
    Uniformity
    Precise measurement, even distribution

    Oil Pump Applications

    Polyester FDY
    High temperature-resistant oil agent avoids oil stains on hot rollers, reducing fiber breakage.
    High Speed Spinning
    Uniform oiling ensures smooth fiber bundles and reduces static electricity-caused production interruptions.

    16 Outlet Oil Pump

    Here is an introduction to an oil pump. If you need other types, please contact us.
    Inlet Ports
    1
    Outlet Ports
    16
    Speed Range
    10 – 60 rpm
    Operation Temperature
    < 50 ℃
    Computer Number Type Capacity Per Port (cc/rev) Dimension (mm)
    S H1 H
    FY00081601 FYB16X0.08 0.08 15.4 84.6 112
    FY00101601 FYB16X0.10 0.10 15.6 85.4 113
    FY00121601 FYB16X0.12 0.12 15.9 86.7 114
    FY00151601 FYB16X0.15 0.15 16.4 88.6 116
    FY00201601 FYB16X0.20 0.20 17.2 91.8 119
    FY00301601 FYB16X0.30 0.30 18.8 98.2 126
    16 Outlet Oil Pump

    Instructions for Using High-Pressure Melt Spinning Metering Pump

    Installation and Operation of the Pump

    1. Spray a small amount of silicone oil into the inlet hole of the cleaned metering pump, and use a special tool to rotate the transmission sleeve for initial lubrication (for use with a new pump, there is no need to disassemble and clean).
    2. Place the pump into the waste heat furnace and raise the temperature at a rate not exceeding 100 ℃/H. The spinning process requires the spinning box temperature to be raised, and perform insulation preheating (4–6 hours).
    3. Install the preheated pump onto the spinning box pump seat, use specialized positioning screws to secure the pump, and keep it warm for about 4 hours before starting to operate.
    4. When driving, first rotate the flange of the spinning machine drive shaft by hand to drive the pump body to rotate smoothly and evenly. You can start the machine and open the feed inlet needle valve in a timely manner to allow the melt to flow into the inlet of the metering pump, preventing the pump shaft from running empty.
    5. In order to prevent accidental damage to the metering pump during operation, the spinning machine drive shaft must have a safety pin (or key) with a strength lower than that of the key on the pump drive shaft.

    Cleaning and Disassembly of Pumps

    1. Place the pump into the box type electric furnace and heat it up to 380–420 degrees at a rate not exceeding 100 degrees/H to carbonize the slurry before disassembly.
    2. Brush the decomposed parts with a nylon brush to remove surface carbides, and clean them thoroughly by placing them in kerosene.
    3. After the metering pump is removed from the spinning box, it should not be rapidly cooled to prevent deformation or cracking of the parts.
    4. The working environment for disassembling, assembling, and repairing metering pumps should be clean and tidy to prevent debris and metal from entering the pump, affecting its accuracy or accidentally damaging its parts.
    5. Each set of pump should establish a record card to record the use, maintenance, damage, flow rate, and other information of the pump.

    Frequently Asked Questions (FAQ)
    Q
    What is the difference between a melt spinning pump and a solution spinning pump?
    Melt spinning pumps are designed for high-temperature melt processes (such as polyester and nylon) and can withstand operating temperatures of nearly 300 ℃ and cleaning temperatures up to 450 ℃. Solution spinning pumps are used in lower-temperature processes (such as acrylic and viscose fiber) and are manufactured from corrosion-resistant and wear-resistant materials suited to the chemical properties of the spinning solution.
    Q
    What displacement range and accuracy do spinning metering pumps offer?
    Spinning metering pumps are available in a displacement range of 0.15–30 CC/r, covering small to large flow requirements. The metering accuracy is ±3%, ensuring consistent fiber density and quality throughout the production process.
    Q
    What are the key technical specifications of the 8 Outlet Spinning Pump?
    The 8 Outlet Spinning Pump is primarily used in POY and FDY filament spinning. It features 1 inlet port and 8 outlet ports, an outlet pressure of 50 MPa, a speed range of 10–40 rpm, a maximum differential pressure of 40 MPa, an operating temperature below 350 ℃, and a cleaning temperature below 450 ℃.
    Q
    Why is an oil pump essential in the chemical fiber spinning process?
    The oil pump precisely controls the application of spinning oil onto fiber bundles with an error of less than 1%. This reduces friction and static electricity between fibers, prevents fuzz, breakage, and fiber merging, and is especially critical for high-speed spinning processes (speeds exceeding 3,000 meters per minute) of synthetic fibers such as polyester and nylon.
    Q
    How should a high-pressure melt spinning metering pump be properly maintained?
    Proper maintenance includes: preheating the pump at a controlled rate (no more than 100 ℃/H) before installation, allowing 4 hours of warm-up before operation, avoiding rapid cooling after removal from the spinning box, cleaning in a controlled environment to prevent contamination, and keeping a detailed record card for each pump to track usage, maintenance, and performance data.
    Q
    What materials are used in spinning pumps and why?
    Spinning pumps are typically manufactured from stainless steel or high-temperature alloys. These materials are selected for their excellent wear resistance, corrosion resistance, and dimensional stability at elevated temperatures (up to 300 ℃ during operation and up to 450 ℃ during cleaning), ensuring long service life and consistent metering accuracy.